If the malfunction persists for 4 minutes after the device shuts down due to compressor protection, the error code will be directly displayed on the indoor unit's screen. Otherwise, pressing the LIGHT button six times within four seconds will display the error code.
Codes:
E2 - RUN indicator off for 3 seconds and blinks twice - Inner spiral defrost protection
Possible reasons:
- Poor air return to the indoor unit
- Incorrect fan speed
- Dirty evaporator
E4 - RUN indicator off for 3 seconds and blinks four times - Compressor overheat protection
Possible reasons:
- Communication problem or damage to EEV (Electronic Expansion Valve)
- Refrigerant leak
- Poor heat transfer
E5 - RUN indicator off for 3 seconds and blinks five times - Overvoltage Protection
Possible reasons:
- Intermittent supply voltage
- Supply voltage too low with a high load
E6 - RUN indicator off for 3 seconds and blinks six times - Communication failure
Possible reasons:
- Installation error
- Board problem in indoor or outdoor unit
HER - HEAT indicator off for 3 seconds and blinks fifteen times - EEPROM error (memory chip)
Solution: Replace indoor unit board
F0 - COOL indicator off for 3 seconds and blinks ten times - Lack of Freon or Block Protection
F1 - COOL indicator off for 3 seconds and blinks once - Malfunction of INTERNAL AIR TEMPERATURE SENSOR
Possible reasons:
- Sensor is broken or damaged
- Circuit problem in temperature detection board
F2 - COOL indicator off for 3 seconds and blinks twice - Malfunction of INTERNAL TEMPERATURE SPIRAL sensor (RT2)
F3 - COOL indicator off for 3 seconds and blinks three times - Outside temperature sensor malfunction
F4 - COOL indicator off for 3 seconds and blinks four times - Malfunction of outdoor temperature sensor
F5 - COOL indicator off for 3 seconds and blinks five times - Compressor temperature sensor malfunction
H3 - HEAT indicator off for 3 seconds and blinks three times - Compressor overload protection
Possible reasons:
- Communication problem or damage to EEV (Electronic Aspiration Valve)
- Refrigerant leak
- OLP damage
H4 - HEAT indicator off for 3 seconds and blinks four times - System overload
Solution: Check for dirt and blockages in evaporator and condenser.
H6 - HEAT indicator off for 3 seconds and blinks six times - No feedback from indoor unit motor
Possible reasons:
- Damaged or blocked indoor fan motor
- Problem with indoor unit board
H7 - HEAT indicator off for 3 seconds and blinks seven times - Sync failure
Possible reasons:
- Incorrect input voltage
- Compressor installation error
- Liquid and gas valve not open
- Damaged EEV (Electronic Expansion Valve) or improper operation
- Poor heat transfer
HEAT indicator off for 3 seconds and blinks eleven times - Air conditioner start failure
Possible reasons:
- Compressor installation error
- Recharge system
- System not balanced before starting compressor
- Compressor error
P7 - HEAT indicator off for 3 seconds and blinks eighteen times - Radiator temperature sensor malfunction
Possible reasons:
- Sensor broken or damaged
- Circuit problem in temperature detection board
P8 - HEAT indicator off for 3 seconds and blinks nineteen times - Radiator temperature sensor overheat protection
Possible reasons:
- Insufficient investment in radiator module
- Outdoor unit board problem
PH - COOL indicator off for 3 seconds and blinks eleven times - High voltage
Possible reasons:
- Voltage greater than 265 V
- Outdoor circuit board circuit failure
PL - HEAT indicator off for 3 seconds and blinks twenty-one times - Low voltage
Possible reasons:
- Voltage below 150 V
- Outdoor circuit board circuit failure
U1 - HEAT indicator off for 3 seconds and blinks thirteen times - Compressor phase failure
Solution: Replace outdoor main board or outdoor unit board
U5 - COOL indicator off for 3 seconds and blinks thirteen times - AC problem detected
Solution: Replace outdoor unit board
U7 - COOL indicator off for 3 seconds and blinks twenty times - Check Valve Malfunction
Possible reasons:
- Voltage lower than 175V
- Check valve clamp assembly loose or broken
- Check valve damaged
UA - HEAD and COOL indicators flash twelve times simultaneously - Configuration errors
Solution: The indoor unit does not match the outdoor unit
UF - HEAD and COOL indicators blink seven times simultaneously - Zero transition protection (indoor unit)
Solution: Replace indoor unit board
UH - HEAD and COOL indicators blink eight times simultaneously - No feedback from external unit motor
Possible reasons:
- Damaged or blocked external unit motor
- Problem with outdoor unit board
UU - HEAD and COOL indicators blink eleven times simultaneously - DC over current
Possible reasons:
- High voltage