Chigo Air Conditioners Error Codes

The CHIGO air conditioning control system indicates any malfunctions through the LED lights on the indoor unit panel. Each detected malfunction corresponds to a specific sequence of LED lights or flashes, representing the error code. In case multiple errors are detected, the control system prioritizes and displays the fault with the highest priority first.

 

Error codes for wall split systems:

  • Room temperature sensor: blinks 1 or lights for 8 seconds (Display: E2)
  • Evaporator Temperature Sensor: blinks 2 or lights for 8 seconds (Display: E3)
  • Air conditioner overheating: blinks 3 or lights for 8 seconds (Display: E8)
  • Pump (Overflow): blinks 4 or lights for 8 seconds (Display: E9)
  • Fan motor: blinks 6 or lights for 8 seconds (Display: E5)
  • No communication with external unit: 7 blinks / 8 seconds (Display: E7)
  • Lid not closed: glows or blinks 3 for 8 seconds (Display: E0)
  • Condenser temperature sensor: glows or blinks 4 for 8 seconds (Display: E1)
  • EEPROM does not work: glows or blinks 6 for 8 seconds (Display: E6)

For three-phase systems:

  • Outdoor temperature sensor: glows or blinks 1 for 8 seconds (Display: E2)
  • Pipe temperature sensor: glows or blinks 2 for 8 seconds (Display: E3)
  • Compressor overheating: glows or blinks 3 for 8 seconds (Display: E7)
  • No inter-unit communication: glows or blinks 4 for 8 seconds (Display: E1)
  • Indication of malfunctions of cassette conditioners: Error decoding (see below)

Indication of malfunctions of cassette conditioners:

  • Defrost: blinks 1 time or does not light up for 1 second.
  • Frost protection: flashes 1 time or does not light for 3 seconds.
  • Room temperature sensor: blinks 2 times or does not glow for 4 seconds.
  • Pipe temperature sensor: flashes 3 times or does not light up for 5 seconds.
  • Error from external unit: blinks 4 times or does not light up for 6 seconds.
  • Block frost protection: blinks 5 times or does not light up for 7 seconds.
  • Low pressure protection: blinks 6 times or does not light up for 8 seconds.
  • Power Protection for External Unit: blinks 7 times or does not light up for 9 seconds.
  • Overheat protection: blinks 8 times or does not light up for 10 seconds.
  • Condensation overflow protection: flashes 9 times or does not light for 11 seconds.

Indication of malfunctions of ducted air conditioners:

 

  • Abnormal sensor temperature (E1)
  • Room temperature sensor (E2)
  • Error from external unit (E3)
  • No inter-unit communication (E4)
  • Overheat / frost protection (E7)
  • Phasing error (E8)
  • Low pressure protection (E9)

Chigo: Error codes for columned air conditioners:

 

  • No inter-unit communication (E1)
  • Room air temperature sensor (E2)
  • Evaporator Temperature Sensor (E3)
  • Low pressure protection (E4)
  • Phasing error (E7)
  • Overheat protection (E8)
  • Error from external unit (E9)

 

Chigo: Fault codes for subceiling split systems:

  • Defrost mode: blinks 1 time or does not light up for 1 second.
  • Frost protection: blinks 1 time or does not light for 3 seconds.
  • Room temperature sensor: blinks 2 times or does not glow for 4 seconds.
  • Evaporator Temperature Sensor: blinks 3 times or does not glow for 5 seconds.
  • Outdoor unit error: blinks 4 times or does not glow for 6 seconds.
  • Anti-freeze protection of indoor unit: blinks 5 times or does not glow for 7 seconds.
  • Low Pressure Error: blinks 6 times or does not glow for 8 seconds.
  • External unit power failure: blinks 7 times or does not glow for 9 seconds.
  • Overheat protection: blinks 8 times or does not glow for 10 seconds.
  • Condensate overflow accident: blinks 9 times or does not light for 11 seconds.

Chigo: CMD intelligent vulti connected series:

 

  • Internal air temperature sensor (E2)
  • Evaporator Temperature Sensor (E3)
  • Error from external unit (E4)
  • Fan motor failure (E5)
  • Defrost mode (E6)